CANLI
xAI, Imagine API’yi 2.0’a Yükseltmeye Hazırlanıyor: Görüntü ve Video Tek…·Microsoft MAI-Cyber-1-Flash’ı Duyurdu·Moonshot AI, Kimi K3 Model Ağırlıklarını ve Teknik Raporunu Açık…
2 Nov 2026 · 20:44 GMT+3
Ai Haber – Türkiyenin Yapay Zeka Haber Portalı
ARAşTıRMA · BILGISAYARLı GöRü arXiv:2610.42152 30 Eki 2026 · v1

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

Nattakorn Kittisut, Roy M. Gabriel, Marly van Assen, Mohammadreza Zandehshahvar, Carlo N. De Cecco, +2 yazar

YAYIN:30 Eki 2026 ALAN:cs.CV

Özet

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

Özetle: Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested.

Özet

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

Orijinal Özet (İngilizce)

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

Kaynak: arXiv:2610.42152 · PDF

BibTeX

@article{kittisut2026gazerib,
  title   = {GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning},
  author  = {Nattakorn Kittisut and Roy M. Gabriel and Marly van Assen and Mohammadreza Zandehshahvar and Carlo N. De Cecco and Elizabeth A. Krupinski and Ali Adibi},
  journal = {arXiv preprint arXiv:2610.42152},
  year    = {2026},
  url     = {https://arxiv.org/abs/2610.42152}
}

Tartışma

Bu habere emoji ile tepki ver

Hizli:

Henüz yorum yok. İlk yorumu siz yapın!

Yapıcı ve saygılı yorumlar bekliyoruz. Topluluk kuralları