CANLI
xAI, Imagine API’yi 2.0’a Yükseltmeye Hazırlanıyor: Görüntü ve Video Tek…·Microsoft MAI-Cyber-1-Flash’ı Duyurdu·Moonshot AI, Kimi K3 Model Ağırlıklarını ve Teknik Raporunu Açık…
22 Oct 2026 · 23:01 GMT+3
Ai Haber – Türkiyenin Yapay Zeka Haber Portalı
ARAşTıRMA · BILGISAYARLı GöRü arXiv:2609.35726 28 Eyl 2026 · v1

Impact of Patient Orientation in Single- and Multi-View Camera Environments for AI-based Rehabilitation Monitoring

Miriama Jánošová, Andreas Lang, Petra Budikova, Jan Sedmidubsky

YAYIN:28 Eyl 2026 ALAN:cs.CV OKUMA:34

Özet

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9,% over the commonly used $0^circ$ frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1,%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

Özetle: Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data.

Özet

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9,% over the commonly used $0^circ$ frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1,%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

Orijinal Özet (İngilizce)

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9,% over the commonly used $0^circ$ frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1,%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

Kaynak: arXiv:2609.35726 · PDF

BibTeX

@article{jnoov2026impact,
  title   = {Impact of Patient Orientation in Single- and Multi-View Camera Environments for AI-based Rehabilitation Monitoring},
  author  = {Miriama Jánošová and Andreas Lang and Petra Budikova and Jan Sedmidubsky},
  journal = {arXiv preprint arXiv:2609.35726},
  year    = {2026},
  url     = {https://arxiv.org/abs/2609.35726}
}

Tartışma

Bu habere emoji ile tepki ver

Hizli:

Henüz yorum yok. İlk yorumu siz yapın!

Yapıcı ve saygılı yorumlar bekliyoruz. Topluluk kuralları